Air conditioning for a home office or garden room
A home office or garden room is one of the best places for air conditioning. These rooms are usually small and full of glass and computers, so they get hot in summer and cold in winter. A wall-mounted split system cools and heats from the same unit, and for most single rooms a small unit of about 2 to 3.5 kW is enough. The parts that need planning are the power supply, especially to a garden room, and the pipe run between the indoor and outdoor units.

Why these rooms suit air conditioning
Glass and computers add heat
Large glazed doors catch the sun, and computers, screens and people all add warmth. Daikin says home offices with several computers need extra cooling.
Heating from the same unit
A split system is an air to air heat pump, so the same unit warms the room in winter and cools it in summer.
Nothing on the floor
The indoor unit sits high on the wall, so there is no heater or fan taking up desk or floor space.
What size unit do you need?
Daikin's starting point is about 0.1 kW of cooling for every square metre, for a typical UK room with a 2.4 metre ceiling and average insulation. A 20 square metre room starts at about 2 kW, and a 35 square metre room at about 3.5 kW.
Before allowing for glass, sun and equipment, which can push it up.
What pushes the size up
- Big south or west facing glass. Daikin suggests 10% to 20% more capacity.
- Several computers, screens or a printer running all day.
- More than two people working in the room: about 0.18 kW extra for each extra person.
- A high ceiling. A 3 metre ceiling has 25% more air than a 2.4 metre one.
- Thin walls or a lightly insulated roof, which many garden rooms have.
These are rules of thumb. The size we fit comes from looking at the actual room.
Will it keep a garden room warm in winter?
Check the heating side too
A unit has a cooling size and a heating size. Daikin's small Comfora outdoor unit keeps heating with outside temperatures down to minus 15°C, so it copes with a normal UK winter.
A garden room loses heat faster than a room inside the house, so we size it for the coldest days as well as the hottest.
The power supply
Air conditioning needs a proper electrical supply. Where that comes from is the main difference between a room in the house and a garden room.
A room in the house
- Usually its own circuit from your fuse board
- A new circuit is notifiable work under Part P of the building regulations
- Fitted by our own electricians
A garden room
- Needs a suitable supply run out from the house
- A new supply is notifiable work under Part P too
- An existing supply is checked to make sure it can carry the extra load
We check the supply on the survey, so the electrics are in the quote rather than a surprise later.
How the indoor and outdoor units connect
Two thin copper pipes, a cable and a small drain run between the indoor unit on the wall and the outdoor unit outside.
- Where the outdoor unit goes
- Usually on the back or side wall of the garden room itself, which keeps the pipes short
- Pipe already allowed for
- Daikin's small Comfora outdoor unit holds enough refrigerant for 10 metres of pipe. Longer runs need extra adding
- Longest pipe run
- 15 metres for that unit, with up to 12 metres of height difference
- Outside the building
- Pipes run in neat plastic trunking on the wall
- Water
- In cooling mode the indoor unit collects water from the air, which drains outside
How ArcticNord fits air conditioning in a home office or garden room
We fit air conditioning in homes first, and in small businesses such as shops, dentists, vets and cafes. We cover Nottinghamshire, Leicestershire, Derbyshire, South Yorkshire and West Yorkshire.
- Step 1
A room by room survey
You book it yourself, as a video call or an in-person visit, so the unit is sized for your room rather than guessed.
- Step 2
A fixed written quote
Agreed before any work begins, with the electrics included. Payment is in stages: 10% when you confirm the order, 15% before installation and 75% on completion.
- Step 3
Fitted by our own team
Our engineers are F-Gas registered, the legal qualification to handle refrigerant, and we use our own electricians for the supply.
- After
Covered for years
Midea's 10 year, Fujitsu's 7 year or Daikin's 3 year warranty, each depending on a yearly service, plus our own 12 month workmanship warranty.
Thinking about air conditioning for your home office or garden room? Book a video call or an in-person survey with ArcticNord and we'll size it room by room and give you a fixed written quote.
Get an AC / Heat Pump QuoteQuestions people ask
What size air conditioner do I need for a garden room?
Daikin's starting point is about 0.1 kW per square metre, so most single rooms need about 2 to 3.5 kW. Lots of glass, strong sun or several computers push that up.
Can air conditioning heat a garden room in winter?
Yes. A split system is an air to air heat pump, so it heats as well as cools. Daikin's small Comfora outdoor unit keeps heating with outside temperatures down to minus 15°C.
Do I need planning permission for air conditioning on a garden room?
In England, a system that heats as well as cools can now be fitted under permitted development, as long as it meets the conditions, including a noise limit at your neighbour's nearest window. Air conditioning that only cools is not covered, and listed buildings are different, so check with your council if you are unsure.
Does a garden room need its own electricity supply for air conditioning?
It needs a supply that can carry the air conditioning safely. If there is no supply, or the existing one is not big enough, a new one is needed, and that is notifiable work under Part P. We check this on the survey.
How far can the outdoor unit be from the indoor unit?
It depends on the model. Daikin's small Comfora outdoor unit allows up to 15 metres of pipe. In a garden room the outdoor unit usually goes on the room's own wall, so the run is short.
Where these facts come from
- Daikin UK size guide: about 0.1 kW per square metre, 20 m2 about 2 kW, 35 m2 about 3.5 kW, 2.4 m ceilings, 3 m ceiling adds 25%, south or we…checked 2026-10-24
- Daikin RXP25M (Comfora 2.5 kW outdoor unit) data sheet, merchant copy: maximum pipe length 15 m, level difference 12 m, pre-charged for 10 m…checked 2026-10-24
- Notifiable electrical work in England: new circuits and consumer units, registered competent person or building controlchecked 2026-10-24
- Permitted development for air source heat pumps including air to air from 29 May 2025, MCS 020(a) noise calculationchecked 2026-10-24
- Permitted development conditions: within the dwelling or its curtilage, 37 dB(A) at nearest habitable room, not cooling only, listed buildin…checked 2026-10-24